Mobile Transformer Substation

  • design
  • April 27, 2024
Technical Values   ARMT-1 ARMT-2 ARMT-3 Rated Primary Voltage kV 3.6 – 40.5 3.6 – 40.5 52 – 245 Rated Secondary Voltage kV 0.23 – 0.6 1 – 24 3.6 – 40.5 Rated Short Circuit Current kA 1 – 10 16 – 50...
EK-1A Download File in various and requested sizes EK-1C Download File in various and requested sizes EK-1B Download File in various and requested sizes ARPK Series Prefabricated Transformer Substations are manufactured in accordance with type tests taken from accredited laboratories, IEC 62271-202 standard and TEDAŞ MYD...

ARSK Serisi Hair Extensions

  • design
  • April 27, 2024
Rated Voltage 11-36 kV Maximum Rated Power (KVA) 2500 kV Dimensions 2-40 Metre Internal Arc Resistance (according to Access A and Access B) 16kA/1sn Protection Class IP 65 D Whether Electrostatic For Special Dimensions satis@armtek.com.tr ARSK Series Sheet Metal Kiosks are transformer and...
Rated Voltage 12-36 kV Maximum Rated Power (KVA) 1600 kV Enclosure Class(IEC 62271-202) 10 kV Internal Arc Resistance (according to Access A and Access B) 16kA/1sn Protection Class IP 23 D Cell Type Test Air Insulated/Gas Insulated Armtek Electric Monoblock Concrete Kiosks produced...

ARME-AIS Series 36 kV

  • design
  • April 27, 2024
Rated Voltage 36 kV Rated Network Frequency Withstand Voltage: 70 kV In the Separation Range (between open contacts): 80 kV Rated Lightning Impulse Withstand Voltage: 170 kV In the Separation Range (Open position): 195 kV Frequency 50/60 Hz Rated Current 630-1250 A Rated...

ARME-AIS 36 kV Schneider Inside

  • design
  • April 27, 2024
Rated Voltage 36 kV Rated Network Frequency Withstand Voltage: 70 kV In the Separation Range (between open contacts): 80 kV Rated Lightning Impulse Withstand Voltage: 170 kV In the Separation Range (Open position): 195 kV Frequency 50/60 Hz Rated Current 630-1250 A Rated...
Rated Voltage 12 kV Rated Network Frequency Withstand Voltage: 28 kV In the Separation Range (between open contacts): 32 kV Rated Lightning Impulse Withstand Voltage: 75 kV In the Separation Range (Open position): 85 kV Frequency 50/60 Hz Rated Current 630-1250 A Rated...

ARME-AIS Series 24 kV

  • design
  • April 27, 2024
Rated Voltage 24 kV Rated Network Frequency Withstand Voltage: 50 kV In the Separation Range (between open contacts): 60 kV Rated Lightning Impulse Withstand Voltage: 125 kV In the Separation Range (Open position): 145 kV Frequency 50/60 Hz Rated Current 630-1250 A Rated...

ARME-AIS Series 12 kV

  • design
  • April 27, 2024
Rated Voltage 12 kV Rated Network Frequency Withstand Voltage: 28 kV In the Separation Range (between open contacts): 32 kV Rated Lightning Impulse Withstand Voltage: 75 kV In the Separation Range (Open position): 85 kV Frequency 50/60 Hz Rated Current 630-1250 A Rated...
Nominal Voltage: 36kV Mains Frequency Withstand Voltage: 70kV Lightning Impulse Withstand Voltage 170kV Rated Current 630 – 3150 A Short Circuit Current 25 – 31.5 kA t= 1-3 seconds Internal Arc Withstanding Current 25 – 31.5 kA t= 1-3 seconds Internal Arc Resistance...